Technical details:

 
   
Dose performance:  
0 to 20 l/h  
   
max. pressure:  
20 bar  
   
Electric tension:  
230V Standard; 120V, 12VDC, 24VAC, 24VDC  
   
Idle stroke digit:  
max. 120 hubs/min.  
   
Pump head:  

PP or PVDF with lips- or ceramic-ball-valve, PVC only for models 20 l/h and for 20 bar
valve sealings: VITON or EPDM
manuel exhaust for models til 15 l/h
automatic exhaust optional available

 
   
Membran:  
PTFE  
   
Accessories:  

PP or PVDF dose valve, foot valve,
each 2m sucking/pressure tube, screws and dowels for a wall montage

 
   
Montage:  
wall montage as standard, optional foot montage (DLXB)  
   
Stroke length adjustment:  
optional for DLXB models only (foot montage) available  
   

Available DLX-models:

 
MA/AD  
analog manual dose with double scale adjustment (0-100% & 0-20%), optional: low level alarm  
   
MA/MB  
digital manual control (0-100%); low level alarm  
   
CC/M  
0/4-20 mA proportional control, low level alarm  
   
VFT/MBB  
proportional dose control with stroke digit multiplicator (1xN),
stroke digit multiplicator with memory (1xN-M) and stroke digit divider (1:N),
digital manual dose, low level alarm
 
   
MF/M  

digital manual dose control (0-100%),
proportional dose control with stroke digit multiplicator (1xN),
stroke digit multiplicator with memory (1xN-M) and stroke digit divider (1:N), 0/4-20 mA proportional control,
low level alarm, timer clock, alarm relais output

 
   
pH-Rx-Cl/M  
integrated control of pH, Redox and chlorine (ppm);
0-14 pH-measurement range;
-1000 - +1400 mV Redox-measurement range;
0-2, 0-20 oder 0-200 ppm, chlorine-Messbereich;
0/4-20 mA Ausgang; alarm relais output; low level alarm
 
   
pH-Rx/MBB  
integrated control of pH, Redox;
0-14 pH-measurement range;
-1000 - +1400 mV Redox-measurement range;
On/Off proportional dose mode; alarm relais output; low level alarm
 
   
CD/M  
integrated conductivity regulation(0-1.000 μS or 0-10.000 μS measurement range);
On/Off proportional dose mode; 0/4-20 mA output; 1/2" conductivity sensor containing;
low level alarm
 
   

Technical data:

 
 
Modell dose-
capacity
(L/H)
max. pressure
(bar)
stroke volume
(ml)
max. stroke digit
(imp/minute)
Media
connection
(IDxAD mm)
electrical
connection
01-15 1 15 0,14 120 4x6 230V, 50-60
HZ
2 10 0,28
3 5 0,42
02-20 2 20 0,28 120 4x6 230V, 50-60
HZ
05-07 5 7 0,69 120 4x6 230V, 50-60
HZ
6 5 0,84
8 2 1,11
08-10 8 10 1,11 120 4x6 230V, 50-60
HZ
10 7 1,39
12 3 1,67
15-04 15 4 2,08 120 4x6 230V, 50-60
HZ
20-03 20 3 2,6 120 4x6 230V, 50-60
HZ